We do in-house 12 lead EKGs and have a diagnostic computer program over-read.

 

We have the two EKGs below:

 

 

 

 

 

Burdick Atria 3000 12 lead Interpretive EKG

 

 

 

 

 

Features

· 3, 4, or 6 channel 12-lead ECG tracings

· Advanced functionality in a compact package

· Easy to use keyboard and menu driven interface

· Industry-leading warranty and service program

· Optional interpretation software based on proven University of Glasgow Interpretive ECG Algorithm

      Communications options, including both wired and wireless connectivity, provide state-of-the-art methods to  

      distribute and store ECGs.

Big Functionality In A Small Package

· Automatic or manual operation facilitates STAT operation.

· High resolution thermal printer prints on standard size or A4 paper for easy reading and storage.

· A variety of printout choices, including 3-, 4-, or 6-channel 12-lead ECG printouts and 3-, 4-, 6- or 12-channel 

      rhythm printouts, to suit the requirements of your practice.

      Extended life battery allows you to collect up to 30 ECGs between recharges.

Advanced Features Improve Accuracy

· AccuPrint restricts ECG printout when leads are not properly attached.

· STABLE baseline filter decreases the level of artifact by assuring that the ECG baseline is stable with no

      distortion of ST measurements.

· Pacemaker algorithm accommodates patients with pacemakers.

· Choice of QTc calculation formulas includes Hodges, Bazett, Framingham and Fridericia.

· R to R interval is displayed in measurement box. Intuitive Operation Saves Time

· Alphanumeric keyboard with intuitive menu selections simplifies operation.

· Backlit LCD screen is easy to read, even in low light situations

· Easy loading paper saves time.

 

Upgrade Options To Suit Your Changing Needs

With a variety of upgrade paths, the Atria 3000 ECG will expand and change with growing needs.
Units purchased without Burdick’s powerful interpretation option can be upgraded at any time.
Systems come with data storage for 4 ECGs with optional expansion path to 40 ECGs.
Communications upgrade options allow the ECG to communicate by fax, modem and Ethernet as well as wireless, Bluetooth®, 802.11b and IrDA. The communications options also feature plain paper printing interface, e-mail direct from the ECG and the ability to transfer tests to a PC for storage and analysis.


A Second Opinion That You Can Count On
The Burdick Atria 3000 utilizes the proven Glasgow Royal Infirmary algorithm for interpretation, providing a silent second opinion. Unlike competitive products, which limit algorithm criteria to age, the Glasgow Royal Infirmary algorithm, developed in the 1970s and continuously updated, bases its analysis on five clinically significant criteria: gender, age, race, medication and classification.

This is critical because ECG results for patients with different demographic profiles and medical conditions can vary greatly. For example, subtle T-wave changes that are considered abnormal for a white male are considered normal for a black male of the same age. An ECG that would represent LVH in a 50- ear-old female may be normal for a 50-year-old male. These are just two examples of hundreds of possible clinical issues that may arise when not using an algorithm that take into account age, gender and race.

University of Glasgow Interpretive ECG Algorithm
(formerly known as the Glasgow Royal Infirmary Algorithm)

The Eclipse Plus and Eclipse 850 ECGs utilize the proven University of Glasgow (UG) interpretive algorithm to provide a "silent second opinion" on the electrocardiogram. Developed by Professor Peter Macfarlane, a pioneer in computerized electrocardiography, the algorithm has been continuously updated and improved over the past 30 years to stay in the forefront of electrocardiograph research. Today, the UG algorithm provides documented sensitivity and specificity, with these unique clinical advantages:
 

· The interpretive program basis its analysis on five clinically significant criteria: age, gender, race, medication and classification

· Clear, reason statements (such as "high voltages in limb leads" instead of "R in I > 1.4 mV") provide insight into interpretive calls.

· A pediatric program, with optional use of V4R instead of V3, and limits based on continuous age-based equations (instead of simple look-up tables), to take into account the unique anatomy and continuous development of the neonate and pediatric patient.

Optional long and short interpretation results give just the right amount of information to suit your needs.

Atria 3000 Communications Options
Combines the familiarity of a traditional ECG device with the efficiency of PCs and network storage.

For those physicians looking for advanced communications and storage features, but prefer a traditional ECG, Burdick’s Atria™ 3000 ECG with advanced communications options combines the best of both worlds. It also allows physicians to combine ECGs from both traditional and PC-based products into a single workflow.

FAA Compliant
Atria 3000 with advanced communications includes modem transmissions that comply with FAA system regulations for ECG testing.

E-mail Colleagues Test Results
E-mail capability allows you to send test results directly from the Atria in a PDF format to colleagues for collaborative efforts. The industry-accepted PDF allows any recipient to review results without purchasing proprietary software.

Print Test Results to Plain-paper Printer
Send results wirelessly from the exam room to a network or standalone plain-paper printer with options 802.11b, USB, Bluetooth, IrDA or Ethernet. The diagnostic-quality printouts contain all the information found on the traditional thermal paper printouts. Integrating plain paper printing into a practice can save thousands of dollars a year in paper costs.

Unlimited Storage
For those practices anticipating or moving to a paperless office, the Atria 3000 with communications offers capabilities for permanently archiving a virtually unlimited number of ECGs on a network or stand-alone PC. Plus, ECG archive retrieval is fast and easy.

Upgrade Kits Available
Previously purchased Atria 3000 units can be updated to include communications. Units must be returned to the factory to receive this upgrade.

Transmit Test Results to EMRs
Now test results can be electronically transmitted from the exam room and imported by EMRs and cardiology management systems with communications options such as Ethernet, RS232 and 802.11b wireless Ethernet. No more scanning and keeping hard copies. Imagine the convenience of attaching an ECG report to the patient’s electronic medical record, keeping all information in one file. Burdick ECGs can be interfaced to most EMR systems.

Protect Your Investment
With comprehensive warranty and service offerings Burdick helps protect your investment from unforeseen service costs, providing one less thing to worry about.

Technical Specifications

Dimensions: 15.0" x 13.125" x 5.5" (381 x 334 x 140 mm)
Weight: 11 lbs (5 kg) (including external power supply)
Display: Backlit 2 x 40 character LCD
Keyboard: Full alphanumeric keypad plus designated quick keys
Data storage: 40 records standard

Power requirements:
> AC operation: 115/230 V AC +/-10%, 50/60 Hz at external power source;
> Battery operation: 14.4 V NiMH rechargeable battery pack;
> Battery duration: 30 minutes continuous printing or 30 ECGs without communications option

Printout
> Printout device: 216 mm thermal dot array;
> Paper dimensions: 8-1/2 x 11 (US letter) or A4;
> Paper type: Thermal sensitive (Burdick Assurance® or Heartline™ paper recommended);
> Chart speeds: 10, 25, 50 mm/sec; Gain: 5, 10, 20 mm/mV Chest or Limb (may be split);
> Printout formats: 3-, 4-, 6-, or 12-channel; additional rhythm formats

Acquisition
> Lead selection: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6, V4R; supports Frank X, Y, Z and Nehb D, A, J, and alternate chest lead (chest lead selection V2R thru V9R + V7,V8,V9);
> Measurement (standard), Interpretation (optional): Diagnosis, measurements and reason statements based on five demographic criteria;
Pacemaker display capability: meets or exceeds ANSI/AAMI EC11-1991;
> Modes: Automatic, rhythm or manual;
> Frequency response: Meets or exceeds ANSI/AAMI EC11-1991 standard;
> Input impedance: Meets or exceeds ANSI/AAMI EC11-1991 standard;
> Electrode offset tolerance: +/- 300 mV; A/D conversion: 4000 samples/second, 10 µV LSB RTI: 5 µV LSB;
> Artifact filter response: 40 Hz, -3db;
> Data resolution: 500 samples/second, 5 µV LSB RTI

Environmental Specifications
> Operating temperature: 50°F to 104°F (10°C to 50°C);
> Operating relative humidity: 20% to 90%, noncondensing;
> Operating atmospheric pressure: 1060 hPa to 700 hPa (-500 ft to 10,000 ft reference to sea level);
> Storage temperature: -4°F to 115°F (-20°C to 45°C);
> Storage relative humidity: 10% to 90%, noncondensing;
> Storage atmospheric pressure: 1060 hPa to 190 hPa (-500 ft to 40,000 ft reference to sea level)

Conforms to standards:
> ANSI/AMMI EC11-1991
> CAN/CSA C22.2 no. 601.2.25
> AZ/NZ5 2064.1/2
> EN 60601-1
> CAN/CSA C22.2 no. 0-M91
> EN 60601-1-2:2001 excluding 36.202.6
> CAN/CSA C22.2 no.
> 601.1S1 UL 2601.1

Safety
> Leakage current: Patient <10 µA, chassis <100 µA;
> Defibrillation protection: to 5000 V, 360J

********************************************************

 

 Burdick EK-10 Electrocardiograph

Burdick EK-10 Electrocardiograph

 

 

Dependable, simple operation in a portable package.   The EK-10 electrocardiograph provides ECG reports quickly and easily from an affordable, compact package. For reports with computerized ECG interpretation, choose the EK10 when simple, non-interpretive reports are desired.

Solid state electronic construction. Thermal array dot printer. Completely portable with optional carrying case. Each strip labeled with calibration pulse, patient ID and acquisition parameters. Optional battery pack.

 

Features:

· Single channel interpretive or non-interpretive ECG recorder

· Patient ID#, Lead Markings and Acquisition parameters annotated on strip

· Single or 3-channel formats

· Battery operation – up to 50 ECGs acquired and printed on a fully charged battery

· Soft touch membrane numeric keypad with confirming audible tone

· One touch automatically initiates printout of classic 12-lead ECG

· 48mm thermal dot array printer

· Chart speeds of 25, 50 mm/sec +/- 2%

· Storage for 30 ECGs (Elite II)

· Fax and transmission option (Elite II)

Warranty:  Three years on parts and labor

Size: 11" x 13" x 3.25" (280mm x 330mm x 81mm)
Weight: 9 lbs (4.1 kg)

                                       

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAGALIA-PINES FAMILY PRACTICE MEDICAL CLINIC